A12B

A12B

Magnetic Amplifier Technology

Output:
24,48,130, 260 VDC
6-500 Amps

Input:
Single Phase: 120/208/220/240/480/600 VAC
Three Phase: 208/240/480/600 VAC

Applications:
Utility
Switchgear
Process Control
Oil Exploration

  
Engineered for the demanding requirements of applications such as switchgear, process control, oil and gas exploration. A12B battery charger power systems are available in output DC voltages of 12, 24, 48, 130 or 260 VDC with output DC currents of 3 to 400 amps. 

• Magnetic Amplifier Technology
• Robust with High MTBF Rating
• Inherent and Electronic Current Limit Protections
• Filtered / Battery Eliminator Chargers
• Reverse Polarity & Blocking Diode
• Secure Remote Monitoring and Communications
• Drip Shield and USCG Accessories

 

Datasheets
User Manuals
Enclosures
AC Input VoltagesSingle Phase 60Hz: 120, 208, 220, 240, 480 or 600
Single Phase 50Hz: 220/240, 380 or 415
Three Phase 60Hz: 208, 240, 480 or 600
Three Phase 50Hz: 220/240, 380 or 415
Power ProtectionAC Fuse, DC Fuse and Current Limit Protection
DC Output Amps and VoltagesDC Amps: 3 to 400 amps
DC Volts: 12, 24, 48, 130VDC (Others
Output Filtering (With or without a battery)30mV RMS for single phase models and 100mV RMS for three phase models
DC Voltage RegulationPlus or minus 0.5% of setting from no load to full load over the specified input voltage, frequency and ambient temperature ranges.
Operating Temperature0 to 50 C (32 to 122 F)
Storage Temperature-40 to 85 C (-40 to 185 F)
Relative Humidity0 to 95% (non-condensing)
MTBFExceeds 250,000 Hours
UL Battery ChargerFile E 319318, Guide BBML
UL Std. No. 1012
C-UL Battery ChargerCAN/CSA
Std. C22.2 No. 107-2
UL Fire Alarm System Power SupplyFile S2768, Guide UTRZ
UL Std. No. 1481

ABS/USCG10BU.S. Coast Guard (USGC)
38GABS Type Approval
38JABS/USCG Single Phase
38KABS/USCG Three Phase
Breakers and Protection011AC Circuit Breaker Single Pole (10KAIC minimum)
012Standard DC Breaker Single Pole 10kAIC
016AC Circuit Breaker Two Pole (10KAIC minimum)
017Standard DC Breaker Two Pole 10kAIC
01BAC Circuit Breaker Three Pole (10KAIC minimum)
01C2P High Interrupting Capacity AC Breaker 65KAIC at 240VAC
01DAC Breaker 2 pole High Int 100KAIC @ 240 VAC, 65KAIC @ 480VAC, 25KAIC @ 600VAC
01F3P High Interrupting Capacity AC Breaker 65KAIC 240VAC
01GAC Breaker 3 pole High Int 100KAIC@ 240 VAC, 65KAIC @ 480VAC, 25KAIC @ 600VAC
01MHigh Interrupting DC Breaker Two Pole 22kAIC
020AC Circuit Breaker Auxilary Switch
021AC Circuit Breaker Accessory / Shunt Trip
023DC Circuit Breaker Accessory / Shunt Trip
027DC Circuit Breaker Auxilary Switch
102DC Blocking Diode (Not Available With Charge Dividers)
107DC Surge Protection
11LLightning Arrestor
140AC Switch Single Pole (For 120V Single Phase Units Only)
141AC Switch Two Pole (For Single Phase Units Only)
143AC Switch Three Pole (For 3 Phase Units Only)
217Reverse Polarity Protection & LED
Communications21JIEC 61850 Ethernet (Offered only with 46 series C.A.P.)
21PDNP3.0 Communications RS232/RS485/Ethernet (Offered only with 46 series C.A.P.)
21QModbus Communications RS232/RS485/Ethernet (Offered only with 46 series CAP)
21SModbus RTU Serial Data Port RS232/RS485 (Offered only with 46 series C.A.P.)
21XSNMP (Offered only with 46 series C.A.P.)
Controls103Remote Sensing
10GLoad Sharing
11VTemperature Compensation (Internal Probe)
11WExternal Temperature Probe 24 Feet
11YExternal Temperature Probe 100 Feet
20QEqualize Fan Control Relay
Alarms03NLow DC Current w/ Light
04JMulti-Mode Equalize Timer & Lights
050Ground Detection Switch 3-position with DC Voltmeter indication
051Ground Detection Alarm with Reset Push button and (1) set form "C" Positive and (1) set form "C" Negative contacts
054AC Power Failure Light
060AC Pilot Light
068Audible Alarm
16CHi/Lo-2 Combination Alarm High/Low DC Voltage, Field Calibrations & Adjustments, Individual Lights and (2) Form
Internal Charge Dividers1002 Battery Charge Dividers NEGATIVE COMMON Internal Charge Dividers May Increase The Case Size. Consult Factory For Case Sizes When Ordering An Internal Charge Divider
1013 Battery Charge Dividers NEGATIVE COMMON Internal Charge Dividers May Increase The Case Size. Consult Factory For Case Sizes When Ordering An Internal Charge Divider
10U2 Battery Charge Dividers POSITIVE COMMON Internal Charge Dividers May Increase The Case Size. Consult Factory For Case Sizes When Ordering An Internal Charge Divider.
10V3 Battery Charge Dividers POSITIVE COMMON Internal Charge Dividers May Increase The Case Size. Consult Factory For Case Sizes When Ordering An Internal Charge Divider
LCD Combined Accessory Packages46ADiscrete LED's for C.A.P w/ Ground Detection
46BDiscrete LED's for C.A.P w/o Ground Detection
46ECombination Alarm Package w/LCD
46GCombination Accessory Package & LVBD
46JDigital Alarm w/ LCD
46LCombination Accessory Package w/ Digital Meter & LVBD
46PAudible Alarm w/ Silance Switch and 46E CAP Package
46QCombination Accessory Package w/ LCD & LVBD
46T46J w/ Audible Alarm & Silance Switch
46UCombination Accessory Package w/ Ground Detection & LVBD
LED Combined Accessory Packages16EDigital C.A.P. System
16JCombination Accessory Package w/ Ground Detection
16PAudible Alarm
16TAudible Alarm w/ Silance Switch
Meters06GZero Center Ammeter with Battery & Load Terminals
06LAC Ammeter +/-2% Accuracy - Single Phase
06MAC Voltmeter +/-2% Accuracy - Single Phase
14VAC Voltmeter +/-2% Accuracy - Three Phase
14WAC Ammeter +/-2% Accuracy - Three Phase
Miscellaneous092Tropicalization Dip (Magnetics Only) - Single Phase
093Tropicalization Dip (Magnetics Only) - Three Phase
09AUL 1481 Listing - This Option Code Must Be Specified When Required (Available for selected models)
10LBattery & Load Terminals (Included With Option Code 46G, 46L, 46Q, 46U & 06G)
11F30mV Filtering (Three Phase Units Only) 30mV Filtering Standard On Single Phase Units
38DCopper Ground Bus Bar
Packages1Option 016, 017, 46E and 46B
2Option 016, 017, 46E, 46B, 10G and 102
3Option 016, 017, 46J and 46A
4Option 016, 017, 46J, 46A, 10G and 102
5Option 016, 017, 46J, 46A and 21P or 21Q or 21J
Wire Markers, Documentation & Special Wiring09LPhysical Parts Location Drawing
09WHeat Shrinkable Wire Markers With Electrical Schematic
097SIS Wire - #16 AWG And Larger (Includes Option 09W)