TPSD (Ferro Resonant Charger)

The La Marche TPSD Battery Charger Series is designed to perform as Power Supply / Battery Eliminator. This model incorporates Controlled Ferroresonant technology to provide the DC system with dependable battery charger.
TPSD Battery Charger Series is engineered for the demanding requirements of Switchgear, Process Control, Oil & Gas and other DC power applications.
The design of the TPSD utilizes special magnetics that optimizes the performance of the charger. It's known for its High Efficiency, High Power Factor, Low Harmonic Distortion and inherent Current Limiting. The MTBF (Mean Time Between Failure0 for this design is conservatively rated at 225,000 hours at 50°C, assuring longevity and a higher return for your dollar.


TPSD Data Sheet 

Instruction Manual - Standard TPSD with LED Display
Instruction Manual - TPSD with LCD/VFD Display 

Stationary Battery Charger Applications


Register Your Product

LED Display
Automatic DC Voltage Regulation
Automatic AC Voltage Compensation
Float/Equalize Mode Switching & LED Indicators (Adjustable FL/EQ voltage levels)
Positive and Negative Ground Detection
AC & DC Surge Protection (MOV's)
AC Input Circuit Breaker
AC "ON" LED Indicator
DC Ouput Circuit Breaker or Fuse
Local & Remote Equalize Capability
Local & Remote Output Voltage Sensing
Output Load Current Sharing
Internal Temperature Compensation
Form "C" Relay Contacts with Adjustable Parameters:
- Summary Alarm
- AC Power Failure
- Low DC Voltage
- High DC Voltage
- High DC Voltage Shutdown (HVSD)
- Low Current
- Positive and Negative Ground (not adjustable)
Alarm Indicators:
- Summary Alarm 
- Low DC Current
- Low DC Voltage
- High DC Voltage / HVSD
- Ground Detection Fault
U.L. 1012, C-UL Listed (for all 60Hz Units)
5-Year Limited Warranty
 





LCD Display (Option 550)                          VFD Display (Option 551)




TPSD units equipped with an LCD or VFD display support the same features as standard units plus the following additions:

2 Line LCD or VFD Display
Push-Button Adjustments for the Charger Output (No Potentiometers), Alarms and Communication Settings 
User-Friendly Menu structure with push-button switches for ease of navigation
Completely Configurable Alarm Systems
- Alarm Thresholds
- Delays
- Contact Operations (Latching/Non-latching)
Alarm Contacts testing capability to confirm functionality (via front panel or remotely with optional communication card)
Additional LED indicators:
- AC Power Fail
- Overload Alarm
- High Voltage Shutdown
Quick Start Instruction on the Front Panel with QR Code Link to the Charger's Instruction Manual
 
AC Input
Voltage range: +/- 10% from nominal
Frequency range: +/- 5%
Single Phase models:
A1: 120VAC/1/60Hz
ABD1: 120/240/208VAC/1/60Hz
BLD1: 240/220/208VAC/1/60Hz
C1: 480VAC/1/60Hz
5BL1: 240/220VAC/1/50Hz
Three Phase models:
BD3: 240/208VAC/3/60Hz
C3: 480VAC/3/60Hz
5G3: 380VAC/3/50Hz
DC Output
DC Amps: 6 to 200 amperes
DC Volts: 24, 48 & 130VDC
DC Ouput Voltage Range - a chart is provided on the last page of the data sheet
Output Filtering (with or without a battery)
30mV RMS for single phase models
100mV RMS for three phase models
DC Voltage Regulation Steady-State
+/- 0.5% of setting from no load to full load over the specified input voltage, frequency and ambient temerature ranges
Dynamic Response (On Battery)
Maximum Voltage Transient will not exceed +/-5% of initial steady-state voltage for a step change from 20 to 100% of the full rated load. Recovery to steady-state voltage regulation does not exceed 200ms and all transient behavior disappears within 500ms.
Audible Noise
Less than 65dBA at any point 5 feet from any verical surface of the enclosure
Load Sharing
Load sharing terminal located inside of unit. When connected, identical La Marche Units are forced to share the load within +/-5% for individual unit outputs greater than 15% of the rated output.
Temperature Compensation
The TPSD can adjust the output voltage level for temperature changes. The adjustment is based off an internal sensor inside the unit or an optional sensor. Temperature compensation is done in steps of approx. -0.001V/cell/C (consult factory for other compensation rates).
Current Soft Start
The output current will gradually increase after the charger is turned on, eliminating surges and overshoot
Current Limit
The charger have an inherent magnetic current limiting feature. Electronic current limiting control circuitry provides for an adjustable value of 50 to 115% of the rated output current
AC Breaker
Single Phase UnitsA two-[p;e breaker opens both legs of the AC service to 208VAC and 240VAC. Breaker opens phase side of 120VAC service.
Three Phase UnitsA three-pole breaker opens all three legs of the AC service.
DC Breaker & DC Fuse
Standard units are equipped with a fuse or a 2-pole circuit breaker. For units equipped with a fuse, an optional breaker is available. Refer to the model chart on the data sheet for further details
Dimensions
overall dimensions and weights are subject to change due to innovative product development and design. When space requirements are critical, please consult factory.
Mounting
Our enclosures are very versatile. Some units can be wall, floor or rack mounted and others can be wall or floor mounted. see the Case Specifications Chart on the last page of the data sheet for further details.
Finish
Pretreated with a seven stage iron phosphate wash, sealer and deionized rinse. Then coated with an environmentally safe and durable ANSI 61 gray Polyester TGIC Minite powder finish.
Operating Temperature
0 to 50C (32 to 122F)
Storage Temperature
-40 to 85C (-40 to 185F)
Relative Humidity
0 to 95% (non-condensing)
Cooling
Convection Cooled